First Aid Equipment and Supplies

Rescue SAM AED – Semi Automatic

Sale!

Rescue SAM AED – Semi Automatic

£725.00£790.00

SKU: N/A Category: Tags: , ,

 

The Rescue Sam AED has been designed to provide simple and direct voice prompts and indications for a straightforward rescue operation. The Rescue SAM AED is lightweight and battery powered for maximum portability. RESCUE SAM is designed to treat Ventricular Fibrillation (VF) and Fast Ventricular Tachycardia (VT)

The Rescue Sam AED comes complete in the box, just insert the battery, plug in the pads and then press the device on to complete the set up. The pads can be stored with the pouch supplied or in the custom manufactured bag (optional).

In the box

  • Rescue Sam AED
  • Adult Pads
  • Disposable Battery
  • User’s Manual

Specifications

Warranty: 8 years
OPERATING MODE: semi-automatic
ENERGY: 200J fixed as new norms AHA 2010
– adult: nominal 200 J into a 50 Ω load
– infant/children: less than 50J using optional attenuated pediatric pads
SHOCK ENERGY ACCURACY: According to IEC EN60601-2-4
PROTOCOL: voice prompts and indicators guide user through protocol
PACEMAKER: detection and rejection
CHARGE CONTROL: automatic by software (arrhythmia detection system and charging control)
CHARGE TIME FROM “SHOCK ADVISED”: <8 seconds, typical with new battery
VOICE INSTRUCTIONS: detailed voice messages guide the rescuer through use of the defibrillator
CONTROLS: shock button, info-button, On/Off button
INDICATORS: LEDs (different colors), info-button
CHARGE COMPLETE INDICATOR:
– Voice prompts (press the shock red button)
– Flashing red shock button
DISARM: once charged, the RESCUE SAM disarms if:
– Patient’s heart rhythm changes to non-shockable rhythm, or
– The SHOCK button is not pressed within 15 seconds after being armed, or
– The Power ON/OFF button is pressed to turn OFF, or
– The defibrillator pads are removed from the patient or the pads connector is disconnected
SHOCK DELIVERY VECTOR: via adult defibrillator pads in the anterior (Lead II) position or via reduced-energy paediatric pads in the anterior-posterior position
PATIENT ISOLATION: type BF
BATTERY:
4year operational life
– 12 Volt DC, 4.2 Ah, lithium manganese dioxide
min.200 shocks or 4 hours of operating time continuous
AUTOMATED AND USER-ACTIVATED SELF-TESTS:
– Daily Self-tests: tests internal circuitry, waveform delivery system, battery capacity, and software.
– Battery Insertion Test: upon battery insertion, extensive automatic self-tests and user-interactive test check device readiness.
DATA RECORDING AND TRANSMISSION:
– Dedicated interface to download data
– Optional special battery pack for data transmission
– Data stored: first 60 minutes of ECG and the entire incident’s events
and analysis decision.
SIZE: 80 x 300 x 270 mm
WEIGHT: 2.2 kg with battery pack installed.